| Typical Uses |
|
Characteristics |
| Self Regulating - Low Temperature |
| Freeze protection for low temperature liquid samples. Can be used without temperature controllers. May be used on semi permanent installations or where moderate flexing and movement is anticipated. |
|
Infinitely Cut-to-Length
Maximum Continuous Exposure and Maintain Temperature: 150°F (65°C)
Maximum Intermittent Exposure Temperature: 185°F (85°C)
Output: 5, 8 or 10 W/Ft *
Hazardous Area Approvals: FM, CSA, CENELEC
T-Rating: T6
Thermostatic Control: Not Required
|

J & P Series Tracers
|
| Self Regulating - High Temperature |
| Temperature maintenance up to 250°F (120°C). Permanent installations with no flexing or movement anticipated. |
|
Infinitely Cut-to-Length
Maximum Continuous Exposure and Maintain Temperature: 250°F (120°C)
Maximum Intermittent Exposure Temperature: 420°F (215°C)
Output: 5, 10, 15 or 20 W/Ft *
Hazardous Area Approvals: FM, CSA, CENELEC
T-Rating: T3 – T2 depending upon output
Thermostatic Control: Required for maintain temp above 150°F (65°C)
|

B & N Series Tracers
|
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Temperature maintenance up to 300°F (150°C) with high exposure temperatures. Also used for freeze protection of high temperature lines. |
|
24” Zone Lengths
Maximum Continuous Maintain Temperature: 300F (150°C)
Maximum Exposure Temperature (Power OFF): 482°F (250°C)
Output: 10 & 20 W/Ft
Hazardous Area Approvals: FM, CSA, CENELEC
Thermostatic Control: Required
|
JV & JN Series Tracers
|
| Constant Wattage |
| Temperature maintenance up to 400°F (205°C) in general purpose areas. Often used for stack gas systems. (See caution note about using zone heaters for this application.) |
|
24” Zone Lengths
Maximum Continuous Exposure and Maintain Temperature: 400°F (205°C)
Maximum Intermittent Exposure Temperature: 400°F (205°C)
Output: 18 W/Ft
Hazardous Area Approvals: None**
Thermostatic Control: Required
|
T, TN & TY Series Tracers
|
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Maintain temperatures up to 450°F (260°C). Stack gas systems. |
|
Factory Fixed Length
Maximum Maintain Temperature: 450°F (230°C)
Maximum Exposure Temperature: 500°F (260°C)
Output: up to 30 W/Ft
Hazardous Area Approvals: None**
Thermostatic Control: Required
|

Series Resistance Tracers
|
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Maintain temperatures up to 500°F (260°C) with high exposure temperatures. Stack gas, combined cycle power generation, oil sands extraction. |
|
Factory Fixed Length
Maximum Maintain Temperature: 500°F (425°C)
Maximum Exposure Temperature: 1100°F (590°C)
Output: up to 30 W/Ft
Hazardous Area Approvals: FM, CSA, CENELEC
T-Rating: determined by application
Thermostatic Control: Required
|

Mineral Insulated Tracers (MI)
|
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
* Nominal output of variable resistance heaters is rated at 50°F (10°C).
** Some resistance and/or zone heater selections may carry hazardous area approvals. Consult factory if hazardous area approval is required.
= Re-circulated fluid or steam tracing has its own set of design and installation issues requiring consideration such as pressure, trapping, and system recovery. The discussion of steam and fluid tracing is not covered in this design guide. For more information on steam and fluid tracing visit our website at http://www.obcorp.com. |
| |
|
|
|